They also may be used in place of high voltage power fuses. They are utilized when there is a need to remotely switch the incoming or outgoing transmission circuits in a substation. Transmission level circuit breakers or circuit switchers are some of the last devices found in a substation. Overloads due to faults or short circuits on the distribution side of the substation are prevented by low voltage protective equipment. Course Outline Basics of functional and protective earthing Touch and step voltages in substations Importance of the switchyard fence in the earth grid. Within the electrical design function, the basic diagrams used are the: A brief mention of these is given in the following paragraphs. These fuses stop the flow of current in the event of an internal fault or short-circuit in the transformer. We require it to run our houses, water supply, lights, fans, domestic appliances. Figure 1 shows the basic process of substation equipment maintenance. Practically, like air and water, electricity has become a basic requirement. Depending on the line voltage, they may be up to six feet long. power grid equipment such as substations need to be repaired and maintained in a. The next device encountered in a substation are the high voltage power fuses. Fundamentals of Electricity, Power Quality & Harmonics: Active and Reactive. (This is the small amount of current needed to set up the magnetic field in the transformer core.) A substation must first be disconnected from its secondary or load side before the primary or high voltage side can be disconnected using the disconnect switch. learn the basics of Distribution Systems, Substation Layouts, Design. It can only break, or "interrupt" the relatively small "magnetizing current" of the substation transformer. This course will guide you through a systematic study of the.
SUBSTATION BASICS PROFESSIONAL
Learn directly from a Global Professional Electrical Engineer with +17 years of Field Experience . This is a practical course that applies to medium and high-voltage industrial utility substations. A Supervisory Control & Data Acquisition (SCADA. It is like a large safety switch with no load breaking capability. Electrical Substation Fundamentals Complete Understanding. A Substation Automation System (SAS) provides facility to control and monitor all the equipment in the substation locally as well as remotely. The purpose of this switch is to disconnect the substation from the incoming line, not to disconnect the transformer from the load. "Gang-operated" because the three separate switches for each phase are operated as a group from a single control "air-break" because the switch operates in air rather than in another medium, such as oil. Part 2 of the course Fundamentals of Modern Electrical Substations is concentrated on substation auxiliary and control systems which play a major role in. The most commonly used switch in small to medium substations is a gang-operated, air-break disconnect switch.

The first device encountered in a substation is typically a disconnect switch.